Maximo 7.5 upgrade

From: marjy_e_harrison (2012-03-15 13:08)

Any 7.5.0.1 Maximo Upgrade experts yet???
We recently upgraded our Maximo 7.1.1.6 to Maximo 7.5.0.1 the end of February.

App Server IBM WebSphere Application Server 7.0
Version IBM Maximo Asset Management 7.5.0.1 Build 20111019-1635 DB Build V7501-00
Tivoli's process automation engine 7.5.0.1 Build 20111019-1635 DB Build V7501-134
Server OS Windows Server 2008 6.0 build 6002 Service Pack 2
Server DB Oracle 11.2 (Oracle Database 11g Enterprise Edition Release 11.2.0.3.0
Everything worked great in Development
– moved it to Test and everything still was working great
– moved it to Production and it was great until our users logged in…
Our users log in to Maximo across the WAN, so the issues that they have, we are unable to recreate on our end.
Basically they are having the following problems:
1. when changing the status – the status changes, but the status dialog box never disappears.
2. Applied the Import/Export feature on the PM application and the Import preview feature does not work – just disappears (this works in the other environments for the users and us)
3. It is very slow going from tab to tab
4. They get a system message that states: There was a communication error with the server which will result in the loss of some of your changes. You must reload the application and enter the information again – click -- reload box—This can happen on any screen and/or tab --
Here are some examples of errors and Debug messages that we have found in the log that may (or may not) pertain to the issues above.
[3/13/12 8:49:00:300 PDT] 0000002e SystemOut O DEBUG: Control 'uploadfile' could not be found in order to process the 'loadData' event. ::
[3/13/12 8:49:00:471 PDT] 0000002e SystemOut O 13 Mar 2012 08:49:00:471 [INFO] [MXServer] [] BMXAA5621I - The data import preview mode is successful.
[3/13/12 8:49:00:580 PDT] 0000002e SystemOut O DEBUG: Control 'ifimport' could not be found in order to process the 'dialogok' event. ::
[3/13/12 8:49:32:639 PDT] 0000002e SystemOut O DEBUG: Control 'changestatus_2_1-pushbutton_pushbutton' could not be found in order to process the 'click' event. ::
[3/13/12 11:29:56:124 PDT] 00000035 SystemOut O 13 Mar 2012 11:29:56:124 [ERROR] [MXServer] [CID-CRON-2898] Failed to send messages.
javax.mail.MessagingException: Exception reading response;
nested exception is: java.net.SocketTimeoutException: Read timed out
[3/14/12 9:35:04:942 PDT] 00000047 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
java.io.IOException: Async IO operation failed (3), reason: RC: 55 The specified network resource or device is no longer available.
[3/14/12 9:47:12:694 PDT] 00000062 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
java.net.SocketTimeoutException: Async operation timed out
at com.ibm.ws.tcp.channel.impl.AioTCPReadRequestContextImpl.processSyncReadRequest
We do have a couple of PMRs out there, but it is slow going, so any ideas would be great!
Any ideas would be great!!
thanks so much,
Marjy E Harrison


From: Shannon Sutton (2012-03-15 09:17)

I have been on 7.5 since August 2011 and I have not seen any of the issues
that you are seeing.. The only difference is I am running SQL Server, but
that should not make a difference.. I wish you luck and hope IBM can solve
your issue..




From: "marjy_e_harrison" <maniacswife@hotmail.com>
To: MAXIMO@yahoogroups.com
Date: 03/15/2012 09:08 AM
Subject: [MAXIMO List] Maximo 7.5 upgrade
Sent by: MAXIMO@yahoogroups.com






Any 7.5.0.1 Maximo Upgrade experts yet???

We recently upgraded our Maximo 7.1.1.6 to Maximo 7.5.0.1 the end of
February.

App Server IBM WebSphere Application Server 7.0

Version IBM Maximo Asset Management 7.5.0.1 Build 20111019-1635 DB Build
V7501-00
Tivoli's process automation engine 7.5.0.1 Build 20111019-1635 DB Build
V7501-134

Server OS Windows Server 2008 6.0 build 6002 Service Pack 2

Server DB Oracle 11.2 (Oracle Database 11g Enterprise Edition Release
11.2.0.3.0

Everything worked great in Development
– moved it to Test and everything still was working great
– moved it to Production and it was great until our users logged in…

Our users log in to Maximo across the WAN, so the issues that they have, we
are unable to recreate on our end.

Basically they are having the following problems:
1. when changing the status – the status changes, but the status dialog box
never disappears.
2. Applied the Import/Export feature on the PM application and the Import
preview feature does not work – just disappears (this works in the other
environments for the users and us)
3. It is very slow going from tab to tab
4. They get a system message that states: There was a communication error
with the server which will result in the loss of some of your changes. You
must reload the application and enter the information again – click --
reload box—This can happen on any screen and/or tab --

Here are some examples of errors and Debug messages that we have found in
the log that may (or may not) pertain to the issues above.

[3/13/12 8:49:00:300 PDT] 0000002e SystemOut O DEBUG: Control 'uploadfile'
could not be found in order to process the 'loadData' event. ::
[3/13/12 8:49:00:471 PDT] 0000002e SystemOut O 13 Mar 2012 08:49:00:471
[INFO] [MXServer] [] BMXAA5621I - The data import preview mode is
successful.
[3/13/12 8:49:00:580 PDT] 0000002e SystemOut O DEBUG: Control 'ifimport'
could not be found in order to process the 'dialogok' event. ::

[3/13/12 8:49:32:639 PDT] 0000002e SystemOut O DEBUG: Control
'changestatus_2_1-pushbutton_pushbutton' could not be found in order to
process the 'click' event. ::

[3/13/12 11:29:56:124 PDT] 00000035 SystemOut O 13 Mar 2012 11:29:56:124
[ERROR] [MXServer] [CID-CRON-2898] Failed to send messages.
javax.mail.MessagingException: Exception reading response;
nested exception is: java.net.SocketTimeoutException: Read timed out

[3/14/12 9:35:04:942 PDT] 00000047 srt E
com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An
error occurred while parsing parameters. {0}
java.io.IOException: Async IO operation failed (3), reason: RC: 55 The
specified network resource or device is no longer available.

[3/14/12 9:47:12:694 PDT] 00000062 srt E
com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An
error occurred while parsing parameters. {0}
java.net.SocketTimeoutException: Async operation timed out
at
com.ibm.ws.tcp.channel.impl.AioTCPReadRequestContextImpl.processSyncReadRequest


We do have a couple of PMRs out there, but it is slow going, so any ideas
would be great!

Any ideas would be great!!

thanks so much,
Marjy E Harrison




This message is for the named person's use only. It may contain confidential,
proprietary or legally privileged information. No confidentiality or privilege
is waived or lost by any mistransmission. If you receive this message in error,
please immediately delete it and all copies of it from your system, destroy any
hard copies of it and notify the sender. You must not, directly or indirectly,
use, disclose, distribute, print, or copy any part of this message if you are
not the intended recipient.



From: peter.males (2012-03-15 14:06)

Hi,
Just as a general thought, check that the user's browser is set to delete temporary files & cookies when the browser is closed, and that the java cache has been emptied & re-set to not save temporary files locally. We found this caused problems when accessing version 6 over the WAN.
NB - Java & IE settings are per User per Machine, so this needs to be done for each user who logs on to the PC.
Hope this helps.
--- In MAXIMO@yahoogroups.com, "marjy_e_harrison" <maniacswife@...> wrote:
>
> Any 7.5.0.1 Maximo Upgrade experts yet???
>
> We recently upgraded our Maximo 7.1.1.6 to Maximo 7.5.0.1 the end of February.
>
> App Server IBM WebSphere Application Server 7.0
>
> Version IBM Maximo Asset Management 7.5.0.1 Build 20111019-1635 DB Build V7501-00
> Tivoli's process automation engine 7.5.0.1 Build 20111019-1635 DB Build V7501-134
>
> Server OS Windows Server 2008 6.0 build 6002 Service Pack 2
>
> Server DB Oracle 11.2 (Oracle Database 11g Enterprise Edition Release 11.2.0.3.0
>
>
>
> Everything worked great in Development
> – moved it to Test and everything still was working great
> – moved it to Production and it was great until our users logged in…
>
> Our users log in to Maximo across the WAN, so the issues that they have, we are unable to recreate on our end.
>
> Basically they are having the following problems:
> 1. when changing the status – the status changes, but the status dialog box never disappears.
> 2. Applied the Import/Export feature on the PM application and the Import preview feature does not work – just disappears (this works in the other environments for the users and us)
> 3. It is very slow going from tab to tab
> 4. They get a system message that states: There was a communication error with the server which will result in the loss of some of your changes. You must reload the application and enter the information again – click -- reload box—This can happen on any screen and/or tab --
>
> Here are some examples of errors and Debug messages that we have found in the log that may (or may not) pertain to the issues above.
>
> [3/13/12 8:49:00:300 PDT] 0000002e SystemOut O DEBUG: Control 'uploadfile' could not be found in order to process the 'loadData' event. ::
> [3/13/12 8:49:00:471 PDT] 0000002e SystemOut O 13 Mar 2012 08:49:00:471 [INFO] [MXServer] [] BMXAA5621I - The data import preview mode is successful.
> [3/13/12 8:49:00:580 PDT] 0000002e SystemOut O DEBUG: Control 'ifimport' could not be found in order to process the 'dialogok' event. ::
>
> [3/13/12 8:49:32:639 PDT] 0000002e SystemOut O DEBUG: Control 'changestatus_2_1-pushbutton_pushbutton' could not be found in order to process the 'click' event. ::
>
> [3/13/12 11:29:56:124 PDT] 00000035 SystemOut O 13 Mar 2012 11:29:56:124 [ERROR] [MXServer] [CID-CRON-2898] Failed to send messages.
> javax.mail.MessagingException: Exception reading response;
> nested exception is: java.net.SocketTimeoutException: Read timed out
>
> [3/14/12 9:35:04:942 PDT] 00000047 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
> java.io.IOException: Async IO operation failed (3), reason: RC: 55 The specified network resource or device is no longer available.
>
>
> [3/14/12 9:47:12:694 PDT] 00000062 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
> java.net.SocketTimeoutException: Async operation timed out
> at com.ibm.ws.tcp.channel.impl.AioTCPReadRequestContextImpl.processSyncReadRequest
>
> We do have a couple of PMRs out there, but it is slow going, so any ideas would be great!
>
>
> Any ideas would be great!!
>
> thanks so much,
> Marjy E Harrison
>


From: pkroseman (2012-03-15 15:16)

Be sure all users clear their browser cache. That can cause multiple interface problems.
> [3/13/12 8:49:00:300 PDT] 0000002e SystemOut O DEBUG: Control 'uploadfile' could not be found in order to process the 'loadData' event. ::
> [3/13/12 8:49:00:471 PDT] 0000002e SystemOut O 13 Mar 2012 08:49:00:471 [INFO] [MXServer] [] BMXAA5621I - The data import preview mode is successful.
> [3/13/12 8:49:00:580 PDT] 0000002e SystemOut O DEBUG: Control 'ifimport' could not be found in order to process the 'dialogok' event. ::
I get the above in the logs when using Data Import from External Systems. The import still works. "Control 'xxx' could not be found to process the 'yyy' event" debug lines do not affect functionality of Maximo from my experience. I mostly ignore them now.
> [3/14/12 9:35:04:942 PDT] 00000047 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
> java.io.IOException: Async IO operation failed (3), reason: RC: 55 The specified network resource or device is no longer available.
>
>
> [3/14/12 9:47:12:694 PDT] 00000062 srt E com.ibm.ws.webcontainer.srt.SRTServletRequest parseParameters SRVE0133E: An error occurred while parsing parameters. {0}
> java.net.SocketTimeoutException: Async operation timed out
> at com.ibm.ws.tcp.channel.impl.AioTCPReadRequestContextImpl.processSyncReadRequest
Async time out errors also appear to not affect functionality. This error shows up maybe a couple times per week. As long as the cron task runs more than it fails, I'm not too concerned.
I'm not an expert and these are just personal experience. Have been running 7.5 for about 5 months.