Are you using the field on the main work order screen ?
From: MAXIMO@yahoogroups.com [mailto:MAXIMO@yahoogroups.com] On Behalf Of weatherfree@tampabay.rr.com
Sent: 07 October 2013 13:58
To: MAXIMO@yahoogroups.com
Subject: [MAXIMO List] RE: Maximo 7 Asset Meter lastreading not getting updated from Condition Monitoring
Matthew - did you figure out this problem ? I'm new to 7.5, however I'm noticing the same behavior. Thanks, Tammy
---In MAXIMO@yahoogroups.com<mailto:MAXIMO@yahoogroups.com>, <maximo@yahoogroups.com<mailto:maximo@yahoogroups.com>> wrote:
In Maximo 7 condition monitoring, we notice creating a point automatically creates a meter for an asset (in the assetmeter table). However, when we enter a measurement from a workorder plan (job plan) or in condition monitoring for that point, the meter last reading and last reading date for the asset doesn't get updated (assetmeter.lastreading, assetmeter.lastreadingdate, assetmeter.lastreadinginspctr). Is this a bug or is there a setting we're missing?
For some reason the opposite works, which doesn't make sense. If we update a meter, a measurement (measurement table) is recorded for the point.
GDF SUEZ E&P UK Ltd (Company Number 3386464), registered in England and Wales with a registered office address at: 40 Holborn Viaduct, London, EC1N 2PB.
**************************************************************************************************************
This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed.